Type of Document Dissertation Author Olgun, Celal Guney Author's Email Address olgun@vt.edu URN etd-01162004-154238 Title Performance of Improved Ground and Reinforced Soil Structures during Earthquakes – Case Studies and Numerical Analyses Degree PhD Department Civil Engineering Advisory Committee
Advisor Name Title James R. Martin II Committee Chair J. Michael Duncan Committee Member James K. Mitchell Committee Member Mahendra P. Singh Committee Member Marte S. Gutierrez Committee Member Martin C. Chapman Committee Member Keywords
- numerical analysis
- finite element analysis
- soil improvement
- soil-structure interaction
- earthquakes
- reinforced soil strustures
Date of Defense 2003-12-12 Availability unrestricted Abstract The 1999 Kocaeli Earthquake (M=7.4) struck northwestern Turkey on August 17, 1999 and caused significant damage in urban areas located along Izmit Bay. The sites that suffered the greatest damages were located primarily in areas of poorest soil conditions, typically containing soft clays and silts and/or loose, liquefiable sands. Because the affected region is heavily developed with infrastructure and there is a preponderance of poor soils, a wide range of soil improvement measures had been used to mitigate anticipated earthquake damages throughout the region. Following the earthquake and significant aftershocks, Virginia Tech researchers traveled to Turkey to investigate the affected area to document geotechnical field performance. Primary focus of the Virginia tech team was given to investigating the performance of improved soil sites and reinforced soil structures. The sites were subjected to ground motions ranging from about 0.10g to 0.35g. The site locations ranged from 0 to 35 km from the zone of energy release. This dissertation presents in detail, the findings from the two most instructive sites. The investigation of these sties involved field reconnaissance, field and laboratory testing of soils, seismic analysis, numerical modeling, and other analytical work.Files
Filename Size Approximate Download Time (Hours:Minutes:Seconds)
28.8 Modem 56K Modem ISDN (64 Kb) ISDN (128 Kb) Higher-speed Access A1_Title.pdf 47.87 Kb 00:00:13 00:00:06 00:00:05 00:00:02 < 00:00:01 A2_Abstract.pdf 63.31 Kb 00:00:17 00:00:09 00:00:07 00:00:03 < 00:00:01 A3_Acknowledgements.pdf 989.29 Kb 00:04:34 00:02:21 00:02:03 00:01:01 00:00:05 A4_TOC.pdf 1.22 Mb 00:05:38 00:02:54 00:02:32 00:01:16 00:00:06 B1_Chapter_1.pdf 165.42 Kb 00:00:45 00:00:23 00:00:20 00:00:10 < 00:00:01 B2_Chapter_2.pdf 22.94 Mb 01:46:11 00:54:36 00:47:47 00:23:53 00:02:02 B3_Chapter_3.pdf 4.26 Mb 00:19:44 00:10:08 00:08:52 00:04:26 00:00:22 B4_Chapter_4.pdf 4.98 Mb 00:23:04 00:11:51 00:10:22 00:05:11 00:00:26 B5_Chapter_5.pdf 193.00 Kb 00:00:53 00:00:27 00:00:24 00:00:12 00:00:01 C1_References.pdf 562.05 Kb 00:02:36 00:01:20 00:01:10 00:00:35 00:00:02 C2_Appendix.pdf 484.88 Kb 00:02:14 00:01:09 00:01:00 00:00:30 00:00:02 C3_Vita.pdf 59.17 Kb 00:00:16 00:00:08 00:00:07 00:00:03 < 00:00:01
If you have questions or technical problems, please Contact DLA.