Title page for ETD etd-02212001-093323


Type of Document Master's Thesis
Author Carter, Casey Joseph
URN etd-02212001-093323
Title Aerodynamic Performance of a Flow Controlled Compressor Stator Using an Imbedded Ejector Pump.
Degree Master of Science
Department Mechanical Engineering
Advisory Committee
Advisor Name Title
Ng, Fai Committee Chair
Burdisso, Ricardo A. Committee Member
Dancey, Clinton L. Committee Member
Keywords
  • Flow Control
  • Compressor Cascade
  • Trailing Edge Blowing
  • Aerodynamic Loss
  • Boundary Layer Suction
Date of Defense 2001-02-09
Availability unrestricted
Abstract
A high-turning compressor stator with a unique flow control design was developed and tested. Both boundary layer suction and trailing edge blowing developed from a single supplied motive pressure source are employed on the stator. Massflow removed through boundary layer suction is added to the motive massflow, and the resulting combined flow is used for trailing edge blowing to reduce the total pressure deficit generated by the stator wake. The effectiveness of the flow control design was investigated experimentally by measuring the reduction in the total pressure loss coefficient. The experiment was conducted in a linear transonic blowdown cascade wind tunnel. The inlet Mach number for all tests was 0.79, with a Reynolds number based on stator chordlength of 2,000,000. A range of inlet cascade angles was tested to identify the useful range of the flow control design. The effect of different supply massflows represented as a percentage of the passage throughflow was also documented. Significant reductions in the total pressure loss coefficient were accomplished with flow control at low cascade angles. A maximum reduction of 65% in the baseline (no flow control) loss coefficient was achieved by using a motive massflow of 1.6% of the passage throughflow, at cascade angle of 0°. The corresponding suction and blowing massflow ratio was approximately 1:3.6. Cascade angle results near 0° showed significant reductions in the loss coefficient, while increases in the cascade angle diminished the effects of flow control. Considerable suction side separation and the presence of a leading edge shock are noticeable as the cascade angle is increased, and contribute to the losses across the stator surface. Also identified was the estimated increase in wake turning due to flow control of up to 4.5°.
Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  Casey_Carters_MS_Thesis.pdf 3.04 Mb 00:14:04 00:07:14 00:06:20 00:03:10 00:00:16

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.