Title Improvement of Ground-Fault Relaying Selectivity through the Application of Directional Relays to High-Voltage Longwall Mining Systems
Degree Master of Science
Department Mining and Minerals Engineering
Advisory Committee
Advisor Name Title
Novak, Thomas Committee Chair
Faria, Claudio Committee Member
Kohler, Jeffrey Committee Member
Nieto, Antonio V. Committee Member
Reid, Gerald Committee Member
Sottile, Joseph Committee Member
Keywords
  • coal mining
  • 4160-V longwall
  • underground mining
  • mine power systems
  • coal electrical safety
Date of Defense 2004-04-26
Availability unrestricted
Abstract
The continuing trend toward larger longwall mining systems has resulted in the utilization of higher system voltages. The increase in system voltage levels has caused the industry to face complexities not experienced with the lower-voltage systems. One such complexity arises from the larger system capacitance that results from the outby configuration commonly used on 4,160-V longwall power systems. Simulations show that during a line-to-ground fault, the larger system capacitance can cause a situation where the ground current sensed by the ground-fault relays in unfaulted circuits is greater than the mandated ground-fault relay pick-up setting. Simulations show that ground-fault relaying selectivity is potentially lost as a result of this situation. Two alternatives were identified which could improve ground-fault relaying selectivity. They are: the application of a directional relaying scheme and increasing the ground-fault relay pick-up setting. It was determined that directional relays have an application to high-voltage longwall power systems as the ground current sensed by the relay in the unfaulted circuits is out of phase with the ground-fault current sensed by the relay in the faulted circuit. Furthermore, it was determined that raising the ground-fault relay pick-up setting by a factor of eight would also improve ground-fault relaying selectivity. A safety analysis considering the potential for electrocution and the power dissipated by the maximum fault resistance showed that increasing the pick-up setting by a factor of eight would have no detriment to safety. Therefore, either method would improve ground-fault relaying selectivity on high-voltage longwall mining systems, yet because of the escalating size of longwall systems, a directional relaying scheme is a longer term solution.
Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  Thesis.pdf 635.86 Kb 00:02:56 00:01:30 00:01:19 00:00:39 00:00:03

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.