Title page for ETD etd-05112010-020238


Type of Document Master's Thesis
Author Bald, Kevin James
URN etd-05112010-020238
Title A study of carbonyl formation within an innovative indoor air pollution abatement system
Degree Master of Science
Department Environmental Engineering
Advisory Committee
Advisor Name Title
Dietrich, Andrea M. Committee Chair
Woods, James E. Committee Member
Keywords
  • Indoor air pollution.
Date of Defense 1993-03-11
Availability restricted
Abstract
Testing was conducted on the pre-prototype unit of an innovative indoor air pollution abatement system which used catalytic ozonation as a mechanism for oxidation and removal of organic contaminants. The system was evaluated for carbonyl production when the system was challenged with chemicals used to simulate polluted indoor air. Carbonyl compounds, which are potentially toxic partial oxidation products, were monitored using EPA Method I P-SA. The objectives of the study were to qualitatively and quantitatively determine if carbonyls were formed in the airstream when the system was operated, and if so, to determine what factors affected the concentrations of these compounds.

Trials were conducted using benzene and 2-butanol as challenge chemicals. A variety of test conditions were used to determine factors affecting carbonyl concentrations, including temperature, presence of challenge chemicals, sample location, relative humidity, presence of ozone in the airstream, and two interaction variables. No carbonyls were detected in the airstream within the air cleaning system when benzene was used as the challenge chemical. When 2-butanol was used, four carbonyls were detected at various stages of the system, under varying conditions. The carbonyls detected during these trials were formaldehyde, acetaldehyde, acetone, and butanone. Statistical analyses of the data indicated that the pre-prototype unit of the air cleaning system caused increased levels of acetaldehyde and butanone, and possibly formaldehyde, in the airstream when challenged with 2-butanol. Acetone concentrations in the system were affected only by humidity conditions.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
[VT] LD5655.V855_1993.B353.pdf 5.19 Mb 00:24:01 00:12:21 00:10:48 00:05:24 00:00:27
[BTD] next to an author's name indicates that all files or directories associated with their ETD are accessible from the Virginia Tech campus network only.

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.