Title page for ETD etd-06222000-22500037


Type of Document Master's Thesis
Author Cook, Wesley Todd
URN etd-06222000-22500037
Title EX VIVO BIOMECHANICS OF A BILATERAL TYPE I/BILATERAL INTERDENTAL PIN AND ACRYLIC EXTERNAL FIXATOR APPLIED TO THE CANINE MANDIBLE
Degree Master of Science
Department Veterinary Medical Sciences
Advisory Committee
Advisor Name Title
Smith, Mark M. Committee Chair
Grant, Wallace Committee Member
Markel, Mark Committee Member
Shires, Peter K. Committee Member
Keywords
  • External Skeletal Fixation
  • Mandible and Fracture
  • Keywords: Canine
Date of Defense 2000-06-16
Availability unrestricted
Abstract
EX VIVO BIOMECHANICS OF A BILATERAL TYPE I/BILATERAL INTERDENTAL PIN AND ACRYLIC EXTERNAL FIXATOR APPLIED TO THE CANINE MANDIBLE

By

Wesley Todd Cook

Committee Chair: Mark M. Smith

Veterinary Medical Sciences

(ABSTRACT)

Bilateral mandibular ostectomies were performed between premolars 3 and 4 in 10 adult canine specimens. A type I external fixator incorporating a full interdental pin was placed stabilizing a 0.5 cm fracture gap. Four different pin configurations were tested in dorsoventral bending five separate times on each of the ten mandibles: 1) intact mandibular bodies with fixator; 2) ostectomized mandibular bodies and complete fixator; 3) ostectomized mandibular bodies with the caudal pins of the rostral fragment cut; 4) ostectomized mandibular bodies with all pins of the rostral fragment cut. The full interdental pin remained intact in all configurations. Total stiffness and gap stiffness were then determined for each fixation geometry on a materials testing machine.

The mean total stiffness(Nm/rads) for the four configurations was 1) 1543.6, 2) 301.6, 3) 290.5, 4) 267.0. The mean gap stiffness(Nm/rads) for the right hemimandible was: 2) 2041.1, 3) 1763.5, 4) 1679.9. The mean gap stiffness of the left hemimandible was: 2) 2110.8, 3)1880.1, 4)1861.1. There was no gap stiffness for the first configuration since a fracture gap was not present.

Two-way ANOVA was performed on the gap stiffness and the total stiffness.

There was a significant decrease in total stiffness between intact mandibles and ostectomized mandibles regardless of external fixator configuration. However, there was not a significant difference in total stiffness or gap stiffness among the different external fixator configurations applied to ostectomized mandible. External fixator configurations with only the full interdental pin engaging the rostral fragment were as stiff as configurations which had two or four additional pins in the rostral fragment for the applied loads. External fixators for rostral mandibular fractures may be rigidly secured with rostral fragment implants applied extracortically avoiding iatrogenic trauma to teeth and tooth roots.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  Wescookl.PDF 569.17 Kb 00:02:38 00:01:21 00:01:11 00:00:35 00:00:03

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.