Title page for ETD etd-07152010-120817


Type of Document Master's Thesis
Author Barnobi, Christopher Louis
URN etd-07152010-120817
Title Improvement In Acoustic Liner Attenuation In Turbofan Engines By Means Of Plasma Synthetic Jet Actuator
Degree Master of Science
Department Mechanical Engineering
Advisory Committee
Advisor Name Title
Fuller, Christopher R. Committee Chair
Papenfuss, Cory M. Committee Member
Wicks, Alfred L. Committee Member
Keywords
  • noise control
  • acoustic liner
  • turbofan
  • plasma synthetic jet actuator
Date of Defense 2010-07-02
Availability unrestricted
Abstract
Despite many advances in aviation noise control over the past 50 years, the industry is continually striving to reduce noise emissions. Turbofan engine acoustic liners are efficient attenuators of engine noise. Plasma actuators have been used as flow control devices in other settings and will now be studied as an enhancement for acoustic liners. A plasma actuator can excite oscillatory flow or a single direction (bias flow). Both flow types are studied as possible means to excite turbofan liners in order to improve the acoustic performance.

Experiments revealed the oscillatory flow as the dominant factor in controlling resonator performance. The phase control of the actuator signal is an important parameter when dealing with the oscillatory flow. The actuator is first applied to a single resonator and then a set of six resonators. The experiments show that with the correct phase, the actuators improved the performance of a single resonator by 3 dB to 5 dB. The results for the array of actuators/resonators mirror the results of a single device.

Beyond the improvements in performance, a number of other factors affect the usefulness of the plasma actuator technology in a turbofan environment. The ability of the actuator to produce plasma is susceptible to small imperfections in the device, and this property will likely be amplified in a perforated sheet with embedded actuators. Additional weight and energy consumed by the actuators is another factor to consider. Finally, plasma actuator operation produces ozone, so environmental effects deserve consideration as well.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  Barnobi_CB_T_2010.pdf 16.39 Mb 01:15:52 00:39:01 00:34:08 00:17:04 00:01:27

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.