Title page for ETD etd-07212010-020350


Type of Document Master's Thesis
Author Earles-Price, Susan N.
URN etd-07212010-020350
Title Estimation of internal consistency and stability reliability using isokinetic segmental curve analysis
Degree Master of Science
Department Health and Physical Education
Advisory Committee
Advisor Name Title
Sebolt, Don R. Committee Chair
Holford, Elyzabeth J. Committee Member
Stratton, Richard K. Committee Member
Keywords
  • Torque
Date of Defense 1988-10-05
Availability restricted
Abstract

Forty normal subjects, 19 males and 21 females, between the ages of 16 and 43 years were studied to examine the reliability of Cybex knee extension curves utilizing Segmental Curve Analysis (SCA). Each subject performed a standardized isokinetic knee extension/flexion test on the Cybex II isokinetic dynamometer. Test protocol consisted of 5 maximum repetitions at a speed of 60 deg/sec. Within one week of the initial test, each subject performed a retest. During testing, all torque and angle measurement information from the Cybex was transmitted to the SCA system. The SCA system plotted, analyzed, and quantified each torque curve for seven specific parameters. The following parameters were quantified by the SCA system: (1) torque at 20 degrees, 70 degrees, and peak torque of knee extension; (2) area of the curve to 20 degrees, 70 degrees and peak torque of knee extension; and (3) area of the torque curve between 20 and 70 degree angles of knee extension. The parameters of peak torque (r=.83 to .97; R=.98 to .99), area to 70 degree angle of knee extension (r=.76 to .87; R=.96 to .98), and area between 20 and 70 degree angles of knee extension (r=.75 to .92; R=.97 to .99) appeared to be the most reliable across trials and days, and were also found to elicit the least amount of variation for both male and female subjects. Coefficients of variation on the parameters of peak torque, area to 70, area between 20 and 70 for females ranged from 15% to 18%. For males, the coefficients of variation for peak torque, area to 70, and area between 20 and 70 ranged from 23% to 27%. Variables quantifying torque and power indices in the middle segment of torque curves appeared to be most reliable as analyzed by the SCA system.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
[VT] LD5655.V855_1988.E274.pdf 3.88 Mb 00:17:59 00:09:14 00:08:05 00:04:02 00:00:20
[BTD] next to an author's name indicates that all files or directories associated with their ETD are accessible from the Virginia Tech campus network only.

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.