Title page for ETD etd-07252002-205926


Type of Document Master's Thesis
Author Sharp, Jennifer M.
URN etd-07252002-205926
Title Development of Immunomagnetic Capture (IMC) Based Techniques For the Detection of Salmonella in Poultry Carcass Rinse Fluid
Degree Master of Science
Department Veterinary Medical Sciences
Advisory Committee
Advisor Name Title
Pierson, Frank William Committee Co-Chair
Sriranganathan, Nammalwar Committee Co-Chair
Sumner, Susan S. Committee Member
Keywords
  • detection
  • poultry
  • rapid
  • Salmonella
Date of Defense 2002-07-12
Availability unrestricted
Abstract
Current detection methods require at least one 24-48 hour enrichment step for the detection of Salmonella. This poses a problem because product often needs to be shipped before microbial contamination levels can be adequately ascertained. Therefore, the need for more rapid methods of Salmonella detection becomes apparent.

The purpose of this thesis was to determine if an immunologically-based method, Immunomagnetic Capture(IMC) -ELISA and molecular-based detection methods, PCR and Taqman® PCR employing IMC without enrichment, could detect at least 102 cfu/ml of S. Typhimurium in broiler carcass rinse fluid (CRF) samples.

IMC-ELISA, IMC-PCR, and IMC-Taqman® PCR were initially tested using 0 to 106 cfu/ml of pure culture S. Typhimurium. Each detection method was tested using artificially contaminated CRF samples. Finally, standardized IMC-ELISA, IMC-PCR, and IMC-Taqman® PCR methods were tested using commercial CRF samples. Salmonella concentrations were verified using a traditional plate method.

IMC-ELISA produced consistent results when detecting at least 104 to 106 cfu/mL of pure culture S. Typhimurium. IMC-ELISA was not able to produce repeatable results when testing artificially contaminated CRF samples. S. Typhimurium was not detected in commercial CRF samples which by virtue of direct plating on XLT-4 were found to contain essentially no Salmonella (<1 cfu/ml).

IMC-PCR was able to consistently detect 102 cfu/ml, whereas IMC-Taqman® PCR was able to detect 101 cfu/ml of pure culture S. Typhimurium. IMC-PCR, required four hours to complete, and it consistently detected 104 cfu/ml of S. Typhimurium in artificially contaminated CRF samples. IMC-Taqman® PCR took 3 hours to perform and was able to detect 103 cfu/ml S. Typhimurium in artificially contaminated CRF samples. The sensitivity, as well as the decreased time requirements of these detection methods, would suggest their usefulness in a commercial processing setting.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  sharpthesis072502.pdf 349.65 Kb 00:01:37 00:00:49 00:00:43 00:00:21 00:00:01