Title page for ETD etd-07302001-133659


Type of Document Master's Thesis
Author Gannett, Robert Ashley
Author's Email Address rgannett@vt.edu
URN etd-07302001-133659
Title Control Strategies for High Power Four-Leg Voltage Source Inverters
Degree Master of Science
Department Electrical and Computer Engineering
Advisory Committee
Advisor Name Title
Boroyevich, Dushan Committee Chair
Chen, Dan Y. Committee Member
Lai, Jason Committee Member
Keywords
  • synchronous frame control
  • Voltage Source Inverter (VSI)
  • non-linear load
  • unbalance load
  • current control
Date of Defense 2001-07-30
Availability unrestricted
Abstract
In recent decades there has been a rapidly growing demand for high quality, uninterrupted power. In light of this fact, this study has addressed some of the causes of poor power quality and control strategies to ensure a high performance level in inverter-fed power systems. In particular, specific loading conditions present interesting challenges to inverter-fed, high power systems. No-load, unbalanced loading, and non-linear loading each have unique characteristics that negatively influence the performance of the Voltage Source Inverter (VSI). Ideal, infinitely stiff power systems are uninfluenced by loading conditions; however, realistic systems, with finite output impedances, encounter stability issues, unbalanced phase voltage, and harmonic distortion. Each of the loading conditions is presented in detail with a proposed control strategy in order to ensure superior inverter performance. Simulation results are presented for a 90 kVA, 400 Hz VSI under challenging loading conditions to demonstrate the merits of the proposed control strategies.

Unloaded or lightly loaded conditions can cause instabilities in inverter-fed power systems, because of the lightly damped characteristic of the output filter. An inner current loop is demonstrated to damp the filter poles at light load and therefore enable an increase in the control bandwidth by an order of magnitude. Unbalanced loading causes unequal phase currents, and consequently negative sequence and zero sequence (in four-wire systems) distortion. A proposed control strategy based on synchronous and stationary frame controllers is shown to reduce the phase voltage unbalance from 4.2% to 0.23% for a 100%-100%-85% load imbalance over fundamental positive sequence control alone. Non-linear loads draw harmonic currents, and likewise cause harmonic distortion in power systems. A proposed harmonic control scheme is demonstrated to achieve near steady state errors for the low order harmonics due to non-linear loads. In particular, the THD is reduced from 22.3% to 5.2% for full three-phase diode rectifier loading, and from 11.3% to 1.5% for full balanced single-phase diode rectifier loading, over fundamental control alone.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  Thesis_final.pdf 1.15 Mb 00:05:19 00:02:44 00:02:23 00:01:11 00:00:06

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.