Title page for ETD etd-08042005-172825


Type of Document Master's Thesis
Author Gardner, Robert Matthew
Author's Email Address rgardner@vt.edu
URN etd-08042005-172825
Title Conditioning of FNET Data and Triangulation of Generator Trips in the Eastern Interconnected System
Degree Master of Science
Department Electrical and Computer Engineering
Advisory Committee
Advisor Name Title
Liu, Yilu Committee Chair
Centeno, Virgilio A. Committee Member
De La Ree Lopez, Jaime Committee Member
Keywords
  • Eastern Interconnected System
  • Hypocenter
  • Hypocentral Loci
  • Electromechanical Wave
  • Frequency Perturbation/Wave Front/Disturbance
  • Frequency Data Recorder
  • FNET
Date of Defense 2005-07-29
Availability unrestricted
Abstract
Using data from the frequency disturbance recorders (FDRs) that comprise the nation-wide frequency monitoring network known as FNET, disturbances in the eastern interconnected system (EI) have been monitored and recorded over the past several years. Analysis of this and other data by a wide variety of research scientists and engineers has rendered the idea that frequency disturbances from generator trips, transmission line trips, load trips, and other events, travel with finite speed as electromechanical waves throughout any power system (in this case the EI). Using FNET data as a tool, it is possible to measure and output the arrival times of these disturbance waves with a time resolution of 100 ms.

To observe with certainty the arrival time of the frequency disturbance waves, field data collected by the FDRs must first be conditioned in a robust manner. The current method that uses the moving mean of raw FDR data is analyzed and two computationally efficient robust methods are suggested in this report. These new methods that rely on robust statistics are more resistant to the effect of outliers contained within the raw FDR data. Furthermore, like the moving mean, these methods smooth the raw data without removing the general trend.

Having recorded and conditioned the FDR data, three conventional triangulation techniques taken from the field of seismology are proposed and analyzed. This study reconfirms the fact that the EI is not a medium of continuous elasticity though which the frequency perturbations travel but rather a discontinuous patchwork of varying elasticities. Within this report, nine generator trip events are analyzed and the aforementioned triangulation methods are applied. The advantages and disadvantages of each method are discussed. To conclude, axioms of future research are proposed and delineated.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  Thesis.pdf 2.49 Mb 00:11:31 00:05:55 00:05:11 00:02:35 00:00:13

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.