Abstract
Threshold leak sizes and leak rates were calculated for a number of liquid food products exhibiting a wide range of surface tension and viscosity values. From this data, one can see that mathematically, under typical pressure differentials generated in food packages (less than or equal to ±34.5 kPa), a leak will never start through a 2 μm defect. The calculated leak rates were compared to calculated evaporation rates. The evaporation rate exceeds the leak rate at lower sized microholes (2, and 5 μm diameter) under typical pressure differentials found in food packages. If the liquid, typically aqueous in food products, is evaporating off faster than the leak itself, then there will be solids left behind that could effectively plug the leak.

The critical leak size is the size micro-defect that allows microbial penetration into the package. The critical leak size of air-filled defects was found to be 7 μm at all pressures tested. This size is considerably important to food packagers because this is when sterility of the package is lost. Previous leak studies have shown that the critical leak size for liquid-filled defects coincide with the threshold leak size and pressure. If this is in fact true, then air-filled defects should exhibit a larger critical leak size than the liquid-filled defects. In this study, air-filled defects were examined. A bioaerosol exposure chamber was used to test micro-defects, nickel microtubes of known diameters 2, 5, 7, 10, 20, and 50 μm hydraulic diameters, against pressure differentials of 0, -6.9, -13.8, and -34.5 kPa.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  etdgibney.pdf 362.11 Kb 00:01:40 00:00:51 00:00:45 00:00:22 00:00:01

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.