Title page for ETD etd-09232008-144706


Type of Document Dissertation
Author Lu, Shu
URN etd-09232008-144706
Title Power transformer magnetization under GIC/GMD
Degree PhD
Department Electrical Engineering
Advisory Committee
Advisor Name Title
Liu, Yilu Committee Chair
Besieris, Ioannis M. Committee Member
De La Ree Lopez, Jaime Committee Member
Johnson, Lee W. Committee Member
Phadke, Arun G. Committee Member
Keywords
  • Geomagnetism
Date of Defense 1994-03-05
Availability restricted
Abstract

Geomagnetically induced currents (GIC) could saturate a transformer core. Two significant effects are the abnormal stray flux in transformers and extremely large harmonic contents in excitation currents, which can lead to serious equipment damage and power system misoperation. Such incidents have occurred during the March 1989 K-9 solar magnetic disturbance.

This dissertation starts with a systematically study of transformer magnetization under GIC. It reviews both dc and ac saturation patterns of five transformer core designs. Magnetic fields along various traverses for dc excitation are presented. Impedance matrix entries of a single phase transformer are compared for normal and dc operations. New observations have been formed based on the simulation results. The study helps to reveal the fundamental transformer magnetization mechanism under GIC in order to assess potential stray flux heating possibilities of geologically vulnerable transformer units.

Based on the finite element analysis, an improved method of modeling transformer excitation under dc bias using equivalent magnetic circuit is developed. There are two unique points in this approach: first, information of 3D finite element magnetic flux distribution analysis is used to construct and verify the circuit model; second, the effect of the transformer tank: is included The model is capable of simulating transformer excitation currents under different levels of dc bias with good accuracy. As a consequence, the complete variations of excitation current harmonics with respect to an extended range of dc bias are revealed. The sensitivity of transformer winding impedances and core loss on the excitation characteristics are examined. The saturated transformer under no-load and various loading conditions is simulated. A laboratory test is performed on a small scale transformer and compared with the model results. Excitation harmonics generated from dc biased three phase transformer banks with different types of equivalent loads are also simulated The effect of both unbalanced dc excitations and unbalanced loads are investigated The results of this study contribute in understanding transformers as harmonic sources and the impact on power systems during a geomagnetic disturbance.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
[VT] LD5655.V856_1994.L8.pdf 5.24 Mb 00:24:16 00:12:29 00:10:55 00:05:27 00:00:27
[BTD] next to an author's name indicates that all files or directories associated with their ETD are accessible from the Virginia Tech campus network only.

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.