Type of Document Master's Thesis Author Holland, Michelle Leigh Author's Email Address cam833@aol.com URN etd-100599-150238 Title Stiffener Design for Beam-to-Column Connections Degree Master of Science Department Civil Engineering Advisory Committee
Advisor Name Title Murray, Thomas M. Committee Chair Easterling, William Samuel Committee Member Holzer, Siegfried M. Committee Member Keywords
- Moment Connections
- Column Stiffeners
- Stiffener Design
Date of Defense 1999-09-08 Availability unrestricted Abstract Stiffeners are used as a means of providing additional support to columns at beam connection locations. They are added when the strength of the column is exceeded but full moment strength of the beam section is desired. In determining the design of column stiffeners, there are no specifications for determining the distribution of load between the column web and stiffeners. The AISC Load and Resistance Factor Design Specifications provides guidelines for determining the stiffener area but no specifications are given. The actual loads taken by the stiffener and web are therefore not truly known.
In this study, experiments were done to determine the load supported by the stiffeners and web when tensile forces are applied to the specimen. The initial stiffener design for the test specimens was based on LRFD guidelines. The actual load distribution between the column web and stiffeners is determined from strain data obtained during testing. This distribution is compared with the assumed loads obtained from the initial LRFD calculations. Finite element analysis is also utilized to confirm the consistency of the results obtained from the experiments. Using this information, a new method is developed which better predicts the distribution of load between the column web and the stiffener.
Files
Filename Size Approximate Download Time (Hours:Minutes:Seconds)
28.8 Modem 56K Modem ISDN (64 Kb) ISDN (128 Kb) Higher-speed Access chapter1.pdf 28.43 Kb 00:00:07 00:00:04 00:00:03 00:00:01 < 00:00:01 chapter2.pdf 81.99 Kb 00:00:22 00:00:11 00:00:10 00:00:05 < 00:00:01 chapter3.pdf 36.11 Kb 00:00:10 00:00:05 00:00:04 00:00:02 < 00:00:01 chapter4.pdf 181.95 Kb 00:00:50 00:00:25 00:00:22 00:00:11 < 00:00:01 chapter5.pdf 15.37 Kb 00:00:04 00:00:02 00:00:01 < 00:00:01 < 00:00:01 post.pdf 78.46 Kb 00:00:21 00:00:11 00:00:09 00:00:04 < 00:00:01 pre.pdf 36.40 Kb 00:00:10 00:00:05 00:00:04 00:00:02 < 00:00:01
If you have questions or technical problems, please Contact DLA.