Title page for ETD etd-10102009-020254


Type of Document Master's Thesis
Author Easter, Christopher
URN etd-10102009-020254
Title Water chemistry characterization and component performance of a recirculating aquaculture system producing hybrid striped bass
Degree Master of Science
Department Environmental Engineering
Advisory Committee
Advisor Name Title
Novak, John T. Committee Chair
Boardman, Gregory D. Committee Member
Libey, George S. Committee Member
Keywords
  • Water chemistry
Date of Defense 1992-06-05
Availability restricted
Abstract

Eight identical and independent pilot scale recirculating aquaculture production systems were populated with fingerling hybrid striped bass (Morone chrysops female x Morone saxatilis male). Three population densities were established with two replicates at 132 fishlm3 and three replicates each at 66 and 33 fishlm3.

Water chemistry and water quality characteristics were monitored throughout the 228 day growth trial for all eight systems. A system component performance analysis was done for both the multi-tube solids clarifier and rotating biological contactor (RBC).

Water chemistry and water quality analysis included dissolved oxygen (DO), alkalinity, ions, carbonaceous biochemical oxygen demand (CBODS), chemical oxygen demand (COD), dissolved organic carbon (DOC), total suspended solids (TSS), volatile suspended solids (VSS), total ammonia nitrogen (TAN) , nitrite and nitrate. The major ions present were chloride, nitrate, sulfate, phosphate, sodium, calcium, magnesium and potassium. Trace levels of TAN, nitrite, iron and copper were also observed. Sodium, calcium and chloride levels were controlled based on a preplaned water exchange and chemical management method. TAN, nitrite and nitrate levels increased over time with increasing feed rates but never reached levels toxic to the fish population. CBODS,COD, DOC, TSS and VSS increased over time increasing as a function of increasing feed rates. No correlation was observed between fish mortality or fish growth rates for the range of organic and solids parameters observed during this study. On average 67% of the TSS present was between 1.5 and 30 microns in size. Diurnal cycles were observed for DO, TAN and alkalinity. The magnitude of these cycles were population dependent.

Multi-tube clarifiers removed an average 56% of all suspended solids in a single pass with 81 % removal efficiency for particles above 70 microns in size. Analysis of the system effluent generated by the clarifier indicates a high degree of similarity between the aquaculture effluent and standard municipal waste on a nutrient basis but with much higher levels of nitrogen and phosphate species.

RBC nitrification performance was fitted to an empirical equation. A nearly constant TAN removal rate was observed over the range of mass loading experienced in this growth trial. This implies that within a reasonable range higher flow rates resulting in higher mass loading will yield higher TAN removal rates for a given RBC.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
[VT] LD5655.V855_1992.E276.pdf 5.02 Mb 00:23:14 00:11:57 00:10:27 00:05:13 00:00:26
[BTD] next to an author's name indicates that all files or directories associated with their ETD are accessible from the Virginia Tech campus network only.

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.