Type of Document Master's Thesis Author DeFreese, James Michael Author's Email Address jdefrees@vt.edu URN etd-12192001-233139 Title Glass Fiber Reinforced Polymer Bars as the Top Mat Reinforcement for Bridge Decks Degree Master of Science Department Civil Engineering Advisory Committee
Advisor Name Title Roberts-Wollmann, Carin L. Committee Chair Cousins, Thomas E. Committee Member Lesko, John J. Committee Member Keywords
- beam end bond tests
- FRP tensile tests
- Fiber Reinforced Polymer (FRP) bars
- Bond of FRP Bars
Date of Defense 2001-12-14 Availability unrestricted Abstract The primary objective of this research was to experimentally investigate material and bond properties of three different types of fiber reinforced polymer (FRP) bars, and determine their effect on the design of a bridge deck using FRP bars as the top mat of reinforcement. The properties evaluated include the tensile strength, modulus of elasticity, bond behavior, and maximum bond stress. The experimental program included 47 tensile tests and 42 beam end bond tests performed with FRP bars. Tensile strength of the bars from the tensile testing ranged from 529 MPa to 859 MPa. The average modulus, taken from all the testing, for each type of bar was found to range from 40 GPa to 43.7 GPa. The maximum bond stress from the beam end bond tests ranged from 9.17 MPa to 25 MPa. From the tests, design values were found in areas where the properties investigated were related. These design values include design tensile strength, design modulus of elasticity, bond coefficient for deflection calculations, bond coefficient for crack width calculations, and development length. The results and conclusions address design concerns of the different types of FRP bars as applied in the top mat of reinforcement of a bridge deck.
A secondary objective was to evaluate the disparity in results between direct pullout tests, and beam end bond tests. Results from the experimentally performed beam end bond test were compared to previous literature involving the direct pullout tests. Results from the performed beam end bond tests were higher than all of the literature using direct pullout results. No recommendations were given on the disparity between the two test methods.
Files
Filename Size Approximate Download Time (Hours:Minutes:Seconds)
28.8 Modem 56K Modem ISDN (64 Kb) ISDN (128 Kb) Higher-speed Access APPENDIXA.pdf 1.26 Mb 00:05:48 00:02:59 00:02:36 00:01:18 00:00:06 APPENDIXB.pdf 804.18 Kb 00:03:43 00:01:54 00:01:40 00:00:50 00:00:04 CH.1(INTRODUCTION).pdf 11.92 Kb 00:00:03 00:00:01 00:00:01 < 00:00:01 < 00:00:01 CH.2(LITREVIEW).pdf 31.96 Kb 00:00:08 00:00:04 00:00:03 00:00:01 < 00:00:01 CH.3(METH&MAT).pdf 152.75 Kb 00:00:42 00:00:21 00:00:19 00:00:09 < 00:00:01 CH.4(RESULTS&DISCUSSION).pdf 113.14 Kb 00:00:31 00:00:16 00:00:14 00:00:07 < 00:00:01 CH.5(CONCLUSIONS).pdf 127.99 Kb 00:00:35 00:00:18 00:00:15 00:00:07 < 00:00:01 FRONTMATTER.pdf 14.57 Kb 00:00:04 00:00:02 00:00:01 < 00:00:01 < 00:00:01 REFERENCES.pdf 7.24 Kb 00:00:02 00:00:01 < 00:00:01 < 00:00:01 < 00:00:01 VITA.pdf 3.04 Kb < 00:00:01 < 00:00:01 < 00:00:01 < 00:00:01 < 00:00:01
If you have questions or technical problems, please Contact DLA.