Abstract:

This work is an experimental study of applying an impedance-based health monitoring technique to complex structures. The work is presented in three parts. In the first part we consider effects of the following three factors on damage detection abilities: actuator excitation level, test wire length and ambient conditions (temperature, structural loading and vibration). It was concluded that increasing the applied voltage improves the signal to noise ratio and damage detection abilities. Test wire lengths under 30m do not affect damage detection abilities. The technique is able to distinguish and detect damage even with variations in temperature, structural loading and vibration. In the second part we apply our health monitoring technique to a complex truss structure and a massive steel steam header. We discovered that with multiplexing (acquiring a single signal from distributed actuators) the actuators on the truss structure we could detect damage but with less location information. Damage detection on the steel pipe ended in inconclusive results. The use of this technique on massive structures needs further investigation. Finally, we conducted a detailed experimental study of monitoring the integrity of composite-reinforced masonry structures. We developed a software package which enables even a casual user to determine if significant damage has occurred in these structures. The technique was successfully applied to detect damage (particularly due to delamination) in these composite-concrete structures. Most significantly, the technique was also able to detect damage well in advance of actual failure. This work relies mainly on frequency response plots and damage metric charts to present the data and to arrive at any conclusions. While frequency response plots give a qualitative approach to the analysis, damage metric charts attempt to quantify the data.

List of Attached Files

APP-A.PDF APP-B.PDF APP-C.PDF
APP-D.PDF APP-E.PDF APP-F.PDF
CHAPTE_1.PDF CHAPTE_2.PDF CHAPTE_3.PDF
CHAPTE_4.PDF CHAPTE_5.PDF CHAPTE_6.PDF
CHAPTE_7.PDF CHAPTE_8.PDF ETD.PDF
REFERE_1.PDF VITA.PDF


The author grants to Virginia Tech or its agents the right to archive and display their thesis or dissertation in whole or in part in the University Libraries in all forms of media, now or hereafter known. The author retains all proprietary rights, such as patent rights. The author also retains the right to use in future works (such as articles or books) all or part of this thesis or dissertation.