Title:Evaluation of MIRE Testing Methods for Rating of an Open-Back Active Noise Reduction Headset
Degree:Master of Science
Department:Industrial and Systems Engineering
Committee Chair: John G. Casali
Chair's email:jcasali@vt.edu
Committee Members:
Keywords:active noise reduction, hearing protection, OSHA standards
Date of defense:April 16, 1997
Availability:Release the entire work immediately worldwide.

Abstract:

EVALUATION OF MIRE TESTING METHOD FOR RATING OF AN OPEN-BACK ACTIVE NOISE REDUCTION HEADSET by Matthew B. Cro Committee Chairman: John G. Casali Industrial and Systems Engineering (ABSTRACT) Active noise reduction was first proposed as a solution for environmental noise over fifty years ago. The use of active noise reduction (ANR) systems, however, was not demonstrated until much later. Recent advances in technology have made the use of active noise reduction systems in personal hearing protection devices (HPDs) practical. Through the use of advanced electronics technology, ANR equipped devices offer the potential to provide increased low frequency attenuation for hearing conservation applications. In order to use ANR equipped devices in an Occupational Safety and Health Administration (OSHA) sanctioned hearing conservation program, a testing standard for ANR equipped HPDs needs to be developed. Existing HPD testing standards offer the most promise for developing an acceptable standard for testing ANR-equipped HPDs. The microphone in real ear (MIRE) testing method is one method that offers a practical method for determining the performance of ANR devices for use in hearing conservation programs. A modified version of this method was successfully used in this study to determine the performance profile of an open-back ANR equipped headset. The results of this and other studies that have used a modified MIRE testing method can be used to support the acceptance of this method as the basis of an approved standard for testing ANR-equipped hearing protection devices.

List of Attached Files

ETD.PDF


The author grants to Virginia Tech or its agents the right to archive and display their thesis or dissertation in whole or in part in the University Libraries in all forms of media, now or hereafter known. The author retains all proprietary rights, such as patent rights. The author also retains the right to use in future works (such as articles or books) all or part of this thesis or dissertation.